Zipper closure 1/4 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Introduction

J2-2NM non-magnetic theodolite is a geomagnetic absolute observation instrument integrating opto-electromechanical technology, which can be used for multiple purposes, like both the geomagnetic declination angle D and the geomagnetic inclination angle I, and observing the total intensity F together with the proton magnetometer is an ideal combination of geomagnetic vector observation. The magnetometer can be used not only in geomagnetic stations, but also for mobile geomagnetic observations in the field. J2-2NM non-magnetic theodolite has the features of high observation accuracy, easy to carry, easy to operate, stable and reliable working performance.

Features

 The resolution reaches up to 2", and the magnetic field at any position of the theodolite within 1cm distance from the direction of the secondary probe is less than 1nT;

 

 The magnetometer part adopts a single-axis fluxgate magnetometer with a resolution of up to 0.1nT;

 

 The system structure is simple, light and portable, which is convenient for station and field construction.

Application

Widely used in geomagnetic scientific research, data collection, mapping, national defense, earthquake prediction, petroleum and various mineral detection, aviation and navigation orientation, and many other fields, the instrument can implement geomagnetic observation at fixed stations or field stations.

Spracification
Theodolite J2 - 2NM non - magnetic theodolite
Theodolite grade better than DJ2
Max. allowable error ΔD: ±0.10", ΔI: ±0.10"
Repeatability δD: ±0.10", δI: ±0.10"
Steering difference ΔD: 5', ΔI: 5'
Min. safety distance from detector to fluxgate sensor 2.0 m
Magnetic interference less than 1nT at the theodolite within 1cm distance
from the direction of the secondary probe
Sensor calibration initial horizontal axis difference: <45", vertical axis difference: <20"
Linearity 0.3% (full scale)
Correction factor 1.000±1%
Indication resolution 0.1nT
Dynamic range -250nT - 250nT
Horizontal included angle 3'
Vertical included angle 3'
Zero field drift adjustable within 20nT
Gauge head display digital
Power supply AC and DC dual - purpose (DC12V, AC220V),
reverse polarity protection, portable charger
Operating temperature -10~+40°C
Free drop height
(under transportation guarantee condition, complies with JB/T5929)
250mm
Note Illustrations, descriptions and technical specifications